Fluke 87 III User Manual: An Overview
This manual details the Fluke 87 III‚ a handheld 4000-count instrument for field and lab use‚ offering performance and accuracy for industrial maintenance professionals.
The Fluke 80 Series III‚ including the 87 III‚ provides a robust solution for demanding applications‚ with comprehensive instructions for optimal operation.
The Fluke 87 III is a highly regarded True RMS multimeter‚ designed for professionals needing reliable measurements in diverse environments. As part of the Fluke 80 Series III‚ it builds upon a legacy of performance and accuracy‚ becoming the original choice for demanding tasks;
This handheld‚ 4000-count instrument excels in field service‚ laboratory work‚ and industrial maintenance. It’s known for its durability and comprehensive feature set‚ offering solutions for voltage‚ current‚ resistance‚ and continuity testing.
This user manual provides detailed instructions to ensure safe and effective operation‚ maximizing the instrument’s capabilities. Understanding these guidelines is crucial for achieving precise results and prolonging the Fluke 87 III’s lifespan.
Key Features and Specifications
The Fluke 87 III boasts True RMS accuracy for AC voltage and current measurements‚ ensuring reliable readings even with complex waveforms. It features automatic and manual ranging‚ providing flexibility for various applications.
Key specifications include a 4000-count display‚ diode test‚ and continuity buzzer. The multimeter offers comprehensive safety ratings‚ including CAT III 600V‚ enhancing user protection.
Additional features encompass Min/Max recording‚ Auto-Hold‚ and relative mode‚ streamlining measurement processes. The Fluke 87 III is designed for rugged field use‚ backed by a dependable build quality and detailed instructions within the user manual.

Getting Started with Your Fluke 87 III
Before operation‚ familiarize yourself with the controls and refer to the Fluke 87 III user manual for complete operating instructions and safety guidelines.
Unboxing and Initial Inspection
Upon receiving your Fluke 87 III‚ carefully inspect the packaging for any signs of damage during shipment. Open the box and verify that all included components are present. These typically include the multimeter itself‚ test leads (potentially a TL20 Industrial Test Lead Set as an optional accessory)‚ and this user manual.
Thoroughly examine the multimeter for any visible defects‚ such as cracks or broken parts. Check the input jacks for any obstructions or damage. Ensure the battery door is securely fastened. If any damage is detected‚ do not use the instrument and contact Fluke Support immediately. Retain the original packaging for potential returns or warranty claims. A quick visual inspection ensures your meter arrives in optimal working condition.
Battery Installation and Replacement
The Fluke 87 III operates on batteries‚ ensuring portability for field measurements. To install‚ locate the battery compartment‚ typically on the rear of the instrument. Open the compartment and insert the correct type of batteries‚ observing the proper polarity (+ and -) as indicated inside the compartment. Ensure the batteries are securely seated.
For battery replacement‚ use only high-quality batteries of the specified type. Low batteries can affect measurement accuracy. The meter may display a low battery indicator when replacement is needed. Always replace all batteries at the same time to prevent issues. Dispose of used batteries responsibly‚ following local regulations. Proper battery maintenance ensures reliable operation of your Fluke 87 III.
Understanding the Front Panel Controls
The Fluke 87 III’s front panel features intuitive controls for easy operation. The central Function Selection Knob allows you to choose various measurement modes like voltage‚ current‚ and resistance. Input Jacks and Connections are clearly labeled for connecting test leads – typically COM (common)‚ VΩmA (voltage‚ resistance‚ and milliampere)‚ and A (amps).
Additional buttons activate features like Auto-Hold and Relative Mode. Familiarizing yourself with these controls is crucial for accurate and efficient measurements. Refer to the detailed diagrams in the full user manual for precise locations and functions of each control; Understanding these elements unlocks the full potential of your multimeter.
Function Selection Knob
The Function Selection Knob on the Fluke 87 III is the primary control for choosing the desired measurement type. Rotating the knob cycles through options including DC Voltage‚ AC Voltage‚ DC Current‚ AC Current‚ Resistance‚ Continuity‚ Diode Test‚ and more.
Each position on the knob corresponds to a specific function‚ indicated by clear markings. Precise positioning is essential for accurate readings. The knob also selects measurement ranges within each function. Consult the user manual for a comprehensive list of functions and their corresponding knob positions to ensure correct operation and optimal performance.
Input Jacks and Connections
The Fluke 87 III features dedicated Input Jacks for various measurements. The COM (common) jack serves as the reference point for all measurements. The VΩmA jack is used for voltage‚ resistance‚ and low-current measurements. The 10A jack accommodates higher current measurements‚ up to 10 amps.
Using the correct jacks is crucial for accurate readings and preventing damage to the meter. Optional accessories‚ like the TL20 Industrial Test Lead Set‚ connect through these jacks. Always ensure secure connections and inspect leads for damage before use. Refer to the manual for detailed diagrams and safety guidelines regarding input connections.

Measurement Functions
The Fluke 87 III offers versatile measurement capabilities‚ including AC/DC voltage and current‚ resistance‚ and continuity testing for comprehensive electrical analysis.
Voltage Measurement (AC/DC)
Measuring voltage with the Fluke 87 III is a fundamental function‚ supporting both AC and DC voltage readings. Ensure proper test lead connections – black to common‚ and red to the voltage measurement input. Select the appropriate voltage range using the function selection knob‚ starting with the highest range if the voltage is unknown.
The meter automatically ranges‚ but manual selection provides greater control. Observe the display for the voltage value and units (mV‚ V‚ kV). For AC voltage‚ the Fluke 87 III provides True RMS measurements‚ ensuring accuracy with non-sinusoidal waveforms. Always adhere to safety precautions when measuring voltage‚ especially in high-voltage environments‚ and consult the full user manual for detailed guidance and safety information.
Current Measurement (AC/DC)
Current measurement on the Fluke 87 III requires careful attention to safety and proper setup. Disconnect power to the circuit before connecting the meter in series with the load. Select the appropriate current range (mA or A) using the function selection knob‚ again starting with the highest range if unknown.
The meter supports both AC and DC current measurements‚ providing True RMS values for AC current. Utilize the correct input jacks – move the red lead to the current input. Caution: Excessive current can damage the meter or test leads; always verify the current level before measurement. Refer to the complete user manual for detailed instructions and safety guidelines regarding current measurements.
Resistance Measurement
Resistance measurement with the Fluke 87 III requires the circuit to be de-energized. Ensure the component being tested is isolated and not part of a live circuit to prevent damage to the meter and ensure user safety. Select the resistance measurement function using the rotary dial‚ starting with the highest range if the resistance value is unknown.
Connect the test leads to the component‚ noting that lead resistance can affect low-resistance readings. The Fluke 87 III displays the resistance value in ohms‚ kilohms‚ or megohms. Refer to the full user manual for detailed instructions and troubleshooting tips regarding resistance measurements‚ including considerations for accuracy and component limitations.
Continuity Testing
Continuity testing on the Fluke 87 III verifies electrical connection between two points. Select the continuity function using the rotary dial; an audible beep indicates a closed circuit (low resistance). Ensure the circuit is de-energized before testing to avoid damage and ensure safety. Connect the test leads to the points being tested.
The meter displays a low resistance value when continuity exists. Note that the sensitivity of the continuity test can be adjusted in the settings. Refer to the comprehensive user manual for detailed guidance‚ including troubleshooting scenarios and considerations for testing various components. Always prioritize safety when performing continuity checks.

Advanced Features

The Fluke 87 III offers Auto-Hold‚ Min/Max recording‚ and Relative Mode for enhanced measurement capabilities and efficient troubleshooting in diverse applications.
Auto-Hold Function
The Auto-Hold function automatically freezes the reading on the display when the measurement stabilizes‚ ensuring you don’t miss crucial data fluctuations. This feature is particularly useful when working in environments with significant electrical noise or when measurements are difficult to visually monitor consistently.
To activate Auto-Hold‚ press the HOLD button on the front panel. The display will show “HOLD” indicating the function is enabled. The meter will continuously monitor the input signal and only display a stable reading once it falls within a predefined tolerance.
When a stable reading is captured‚ the display freezes‚ and the “HOLD” icon remains visible. Pressing the HOLD button again disables Auto-Hold‚ returning the meter to normal operation and displaying real-time measurements.
Min/Max Recording
The Min/Max recording function captures the highest and lowest readings encountered during a measurement period‚ providing valuable insight into signal variations. This is incredibly useful for identifying intermittent issues or assessing the range of values within a system.
Activate this feature by pressing the MIN/MAX button. The display will initially show “MAX‚” indicating it’s recording the maximum value. Subsequent presses cycle through “MIN” for minimum value recording‚ and then back to real-time measurement.

The current maximum or minimum value is displayed‚ along with a small icon indicating whether it’s showing the “MAX” or “MIN” reading. Pressing MIN/MAX again returns to normal measurement mode‚ clearing the recorded values.
Relative Mode
Relative mode allows you to establish a new zero point for measurements‚ displaying subsequent readings as deviations from that baseline. This is particularly helpful when comparing values or isolating changes in a circuit.
To activate relative mode‚ press the REL button. The display will show “REL‚” and the current reading will be stored as the reference value. All subsequent measurements will then be displayed as the difference between the current reading and the stored reference.
This function effectively zeroes out the initial reading‚ allowing you to focus on changes. Pressing REL again cancels relative mode‚ returning to absolute measurements.

Safety Considerations
The Fluke 87 III is CAT III rated; always use properly insulated test leads and follow safety guidelines for electrical work.
CAT III Safety Rating
The Fluke 87 III multimeter is designed and tested to meet stringent safety standards‚ specifically a CAT III safety rating. This categorization indicates the meter is suitable for use in measurement categories involving fixed loads‚ such as distribution panels‚ and other heavy-duty industrial equipment.
CAT III instruments can withstand transient overvoltages up to 3000V peak. However‚ it’s crucial to understand that a safety rating doesn’t eliminate all hazards. Always exercise caution when working with live circuits and adhere to established safety procedures.
Proper use of the meter‚ including appropriate test lead selection and awareness of the measurement environment‚ is paramount for safe operation. Refer to the full user manual for detailed safety information and guidelines.
Proper Use of Test Leads
Test leads are essential components for accurate and safe measurements with the Fluke 87 III. Always inspect leads for damage – cracks‚ breaks‚ or worn insulation – before each use‚ replacing them if any defects are found. Use only Fluke-approved test leads or leads of equivalent quality.
Ensure the lead insulation matches the voltage rating of the circuit being tested. For CAT III environments‚ utilize leads specifically rated for this category. Proper connection to the meter and the circuit is vital; secure connections minimize noise and ensure accurate readings.
Avoid touching the metal probes while taking measurements. Refer to the user manual for guidance on selecting the appropriate leads for specific applications and maintaining their condition.

Troubleshooting
This section details common issues‚ solutions‚ and error code meanings for the Fluke 87 III‚ aiding in quick diagnosis and resolution of measurement problems.
Common Issues and Solutions
Experiencing inaccurate readings? First‚ verify battery condition and replace if necessary‚ as low power impacts precision. Continuity beeping intermittently? Ensure clean test lead connections and check for damaged insulation. Meter displays “OL”? This indicates an overload; switch to a higher range or use appropriate test leads.
If the display is dim‚ adjust the contrast or consider a new battery. For unresponsive buttons‚ try cleaning the front panel. If encountering unexpected behavior‚ a reset (refer to the full manual) might resolve the issue. Always consult the Fluke 87 III user manual for detailed troubleshooting steps and safety precautions before attempting any repairs.
Error Codes and Their Meanings
The Fluke 87 III utilizes error codes to signal specific issues. A displayed “Lo Bat” indicates low battery voltage‚ requiring immediate replacement. “OL” signifies an overload condition – exceed the measurement range or utilize appropriate leads. An intermittent display or unusual readings may suggest internal faults‚ necessitating professional servicing.
Specific codes‚ detailed in the comprehensive user manual‚ pinpoint component failures or calibration needs. Ignoring error messages can lead to inaccurate measurements and potential safety hazards. Always refer to the official Fluke documentation for a complete list and corresponding solutions. Proper interpretation of these codes ensures accurate diagnostics and reliable operation of your multimeter.

Resources and Support
Download the full Fluke 87 III user manual online for detailed instructions. Visit the official Fluke support website for FAQs and assistance.
Downloading the Full User Manual
Accessing the complete Fluke 87 III user manual is straightforward and provides in-depth information beyond this overview; The full manual‚ often available in PDF format‚ contains detailed explanations of every function‚ safety precaution‚ and troubleshooting step.
You can typically find the downloadable manual on the official Fluke website’s support section. Search for “Fluke 87 III manual” or browse the digital multimeter product pages. The document‚ potentially converted from a previous format‚ may include diagrams and images for clarity.

Ensure you download the correct version (e.g.‚ international) corresponding to your specific model. Having the full manual readily available ensures you can maximize the capabilities of your Fluke 87 III and address any operational questions effectively.
Fluke Support Website
Fluke Corporation’s official support website is a valuable resource for Fluke 87 III users‚ offering a wealth of information beyond the downloadable manual. Here‚ you’ll find frequently asked questions (FAQs)‚ application notes‚ and troubleshooting guides to assist with common issues.
The website provides access to firmware updates‚ ensuring your multimeter operates with the latest features and improvements. You can also connect with Fluke’s technical support team for personalized assistance.
Furthermore‚ the support portal often features videos and tutorials demonstrating specific functions and best practices for using your Fluke 87 III. Explore the site to unlock the full potential of your instrument and resolve any operational challenges efficiently.